| REQUIREMENTS |
ISO 16183 |
BG-3 |
| System Response Time: |
=< 0.5 second |
0.3 second |
| Input Method of Exhaust Gas |
|
|
| 1.Direct method Any of the 4 mass flow |
|
|
| 2.Air & fuel measurement methods@(Gexhw = Gairw + Gfuel) |
|
|
| 3.Tracer measurement method |
|
|
| 4.Air flow and air to fuel ratio measurement method |
|
|
Proportionality:
Correlation coefficient R2 of the linear regression between Gp,i and GEXH,i >0.98 shall not less than 0.9. The standard error of estimate of Gp,i on GEXH,i shall not exceed 5% of Gp maximum. 1-2% Gp intercept of the regression line shall not exceed +/- 2% of Gp maximum. |
Must Meet requirement |
Meets requirement |
Filter size:
Particulate filters must have a minimum diameter of 47mm. Larger diameter filters are acceptable. |
Must Meet requirement |
47mm, 70mm |
Primary and back-up filters:
The diluted exhaust shall be sampled by a pair of filters placed in series ( one primary and one secondary) during the test sequence |
Must Meet requirement |
Meets requirement |
Filter face velocity:
A gas face velocity through the filter of 35 to 100 cm/s Meets requirement The pressure drop increase between the beginning and the end of the test shall be no more than 25kPa |
Must Meet requirement |
Meets requirement |
Filter loading:
Minimum filter loading shall be 0.25 mg for filter size of 70mm and below. |
Must Meet requirement |
Meets requirement |
| Accuracy of Gtotw: |
+/- 2% |
+/- 2% or less |
| Accuracy of Gdilw: |
+/- 2% |
+/- 2% or less |
Additional specifications:
All parts of the dilution system in contact with raw and diluted exhaust gas must be designed to minimize deposition or alteration of the particulates |
Must Meet requirement |
Meets requirement |